Heating Element 24 V, 180 W, with stainless steel cover and cable connection box installation in to the trough.
Frost protection down to -20 C
Transformer 230/24 v is necessary.
To ensure a frost-free feed pipe, a frost protection heating cable 24 V, 20 W, 2 m
Heating element 24 V, for installation into the trough
Heating element 24 V, 180 W, Model 6063 (Order Ref. 131.6063), with stainless steel cover and cable connection box inclusive. Frost protection of trough down to -20°C. For installation only four boring holes have to be drilled into the trough’s bottom according plan.
For power supply a SUEVIA Transformer 230/24 V is necessary: Model 390 or Model 392. For automatic switch on/off of transformer a thermostat (Order Ref. 101.0389) can be additionally installed (see p. 25). To ensure a frost-free feed pipe, a frost protection heating cable 24 V, 20 W, 2 m (Order
External Heater Panel
Heating Element 24 V, 180 W, with stainless steel cover and cable connection box installation in to the trough.
Frost protection down to -20 C
Transformer 230/24 v is necessary.
To ensure a frost-free feed pipe, a frost protection heating cable 24 V, 20 W, 2 m
Heating element 24 V, for installation under the trough
Easy fixation under the trough
No sharp edges when cleaning the trough
Provides frost protection of the trough down to approx. -20°C
To ensure a frost-free feed pipe, a frost protection heating cable 24 V, 20 W, 2 m (Order Ref. 101.0861), or a 24 V, 30 W, 3 m (Order Ref. 101.1863) has to be used. The
heating cable should be wrapped around the pipe and connected to the heating element of the drinker in parallel to the power supply cable, coming from the transformer.
For power supply a SUEVIA Transformer 230/24 V is necessary (for correct choice of transformer, see p. 25). For automatic switch on/off of transformer a thermostat.
Heater Cable with thermostat
Heating cable with thermostat 24 V, 180 W, cover water lines frost free.
Frost protection down to -20 C
Transformer not necessary.
To ensure a frost-free feed pipe, a frost protection heating cable 230 V, 2 m
Heating cable is delivered with installed thermostat, 2 m (6,6″) connecting cable and plug for 230 V. The heating output amounts to 10 W per meter.
Installation has to be done in parallel to the stainless steel tube underside. Even in very cold ambient temperatures the frost protection heating cable prevents cold water pipes (up to 1″ ) from freezing. The thermostat, situated at the end of the cable, has to be mounted in the coldest place and automatically switches on at +5°C (41°F) and off
when temperature is higher than +15°C (59°F). The water line pipes must be insulated.
In close vicinity of animals the frost protection heating cable should be protected against being bitten by the animals or other damages.
The heating cable must not be shortened! Remaining rests can be winded around the steel pipe. SUEVIA frost protection heating
cables are available in indicated fix lengths. Wire voltage is 230 V – a residual current device has to be provided by the customer. VDE approved quality.
If this heating cable is installed on appropriate plastic pipes, make sure that this water pipe is suited for warm and cold water. For better heat distribution the plastic water pipe has to be wrapped first with an aluminum adhesive tape (Order Ref. 101.1099).
To ensure a frost-free feed pipe, a frost protection heating cable V24 V, 20 W, 2 m
Provides frost protection for feed pipes in galvanized steel or appropriate plastic!
Highly recommended to ensure a frost-free feed pipe leading to e.g. Model 25R-H, 46, 340-H, 500, 520, 600, 620 and all types of troughs.
Frost protection heating cable is wrapped around the water pipe and connected to the transformer like the heating element of the drinker. If plastic pipes are used, they must first be wrapped with an aluminum adhesive tape. All water line pipes must be insulated.
Heating Unit with Return Flow Temperature Control
Provides frost-protected water in insulated water circuits (¾” or 1″ pipe) for circuit length max. 350 m
Designed for use in exposed locations and free stalls especially for cattle, horses,
pigs and sheep. Animals are provided with water in a reliable way, even in very frosty conditions.
Cage of heating element in premium cast iron, enameled
Heating unit Model 312 is equipped with 6000 W (2x 3000 W, 400 V heating elements) and a high-capacity circulation pump with stainless steel base (230 V, 400 W)
The unit is factory-mounted on a plate and ready for installation. Water connections are hold in 1″.
With return flow temperature control: Desired return water flow temperature is regulated by a sensor mounted on the return flow pipe. If return flow water temperature is lower than the adjusted value, the heating element will be automatically switched on.
Heating elements are thermostatically controlled and equipped with an overheating protection (STC)
Scope of delivery includes vent-valve, pressure relief valve, non-return valve, and non-return flap
Two residual-current devices 30mA have to be provided by the customer. They serve to secure the pump and the heating elements in a separated way.